Clinical challenges 2027

Challenge Descriptions

1. Fastest T2-Weighted Liver MRI Without Fat Suppression

The aim is the shortest possible acquisition time for an axial T2-weighted liver scan without fat suppression. Teams are free to choose how they acquire the images, including sequence type, acceleration, reconstruction (including deep learning), field strength, vendor, and breath-hold or free-breathing approach, provided the images meet the requirements below and they declare what they used. To qualify, each submission must meet all of the following requirements in a single healthy volunteer. It must cover the whole liver from the hepatic dome to the inferior margin, at least 14 cm craniocaudally. Acquired voxels must be 1.5 × 1.5 mm in-plane or smaller, with contiguous slices of 5 mm or thinner and no gaps or interpolation. The images must show T2-weighted contrast typical of clinical liver imaging, with fluid such as the gallbladder clearly brighter than the liver and spleen, as judged by the readers. Two blinded readers must judge image quality adequate for liver assessment, with a score of at least 3 out of 5 for overall quality and artefacts. Among qualifying submissions, points go to the three shortest acquisition times, measured from the start of the first acquisition to the end of the last, and ties are broken by the higher image-quality score.

2. High-Resolution, Distortion-Corrected Breast DWI

The objective is to achieve high-resolution, distortion-corrected breast diffusion-weighted imaging (DWI) within a clinically acceptable acquisition time of 10 minutes or less. Current DWI spatial resolution often limits reliable anatomical visualisation and lesion assessment, restricting its potential as a breast cancer screening modality. The challenge is to achieve high, preferably isotropic, spatial resolution, reliable anatomical correspondence with T1-weighted imaging, and minimal susceptibility-related geometric distortions to facilitate accurate image registration. The ultimate goal is to establish diagnostically useful breast DWI that can be integrated into a clinically feasible screening protocol.

3. Multi-Vendor Reproducibility of Meso-Vein Imaging

The objective is to assess the feasibility and reproducibility of meso-vein imaging across different MRI vendors at 3 T. Mapping intracortical veins provides valuable information on cortical vascular architecture, with applications in cognitive neuroscience and the assessment of cerebrovascular health. The challenge is to implement a T2*-weighted acquisition capable of visualising cortex-traversing veins at a target isotropic resolution of 0.35 mm and an echo time of 45–60 ms, while maintaining feasible acquisition times. Participating teams will evaluate vein visibility and consistency of detection across scanner platforms to establish a reproducible multi-vendor imaging approach.